A AbyssalmedMEDICAL EQUIPMENT
Home/Products/Ventilators

Ventilators
for Critical Care and Transfer

Support for both invasive and non-invasive ventilation, with fine adjustment of volume, pressure and respiratory rate, plus alarms that help the clinical team respond in time.

ICUPatient TransferEmergency DepartmentCritical Care
PART 01

Available Models

Choose by duration of use and transport conditions. Transport models are compact and run on an internal battery.

AS-V3
ICU Ventilator

An ICU ventilator with fine adjustment, supporting patients from adults down to infants.

  • VCV, PCV, SIMV, PSV, CPAP modes
  • Adjustable PEEP and FiO2
  • Pressure and volume waveforms
  • 72-hour event log
AS-V3A
Advanced ICU

A model with extended monitoring capability and advanced ventilation modes, for intensive care units handling complex patients.

  • APRV and PRVC modes
  • Near-patient volume measurement
  • Large display
  • Central station connectivity
AS-V1
Transport Ventilator

A compact ventilator for ambulances and intra-hospital transport, powered by an internal battery.

  • Lightweight with carry handle
  • 4–6 hour battery
  • Vibration resistant
  • Dedicated transport modes
AS-NV
Non-invasive

A non-invasive ventilator for patients who are still breathing spontaneously, using a mask or nasal interface.

  • CPAP and BiPAP modes
  • Two-level pressure adjustment
  • Suited to COPD and OSA
  • Usable on general wards
PART 02

Clinical Applications

Choose according to the tier of the facility and the patient profile it handles; our sales team can advise on the basis of actual use.

Intensive care unit

The AS-V3 and AS-V3A are used for patients requiring continuous ventilation, with close monitoring of pressure and volume.

Inter-hospital patient transfer

The AS-V1 maintains ventilation during transfer, which is the highest-risk period.

Chronic care

The AS-NV is used alongside chest physiotherapy in COPD patients who do not require invasive ventilation.

Emergency department

Keep ventilators ready for temporary ventilation before transfer to the intensive care unit.

PART 03

Technical Data by Model

Each model has its own table. The values shown are those declared by the manufacturer in the model datasheet, not independent test results — please confirm the values your clinical use depends on in the quotation before ordering.

AS-V3ICU Ventilator · ICU & Transport Ventilator
Ventilation modesVCV, PCV, SIMV, PSV, CPAP
Tidal volume range (VT)20 – 2000 mL
Respiratory rate1 – 60 breaths/min
PEEP / FiO2PEEP 0 – 30 cmH2O · FiO2 21 – 100 %
DisplayColor screen showing pressure, flow and volume waveforms
Battery / standardsInternal backup power · IEC 60601-2-12
AS-V3AAdvanced ICU · ICU & Transport Ventilator
Ventilation modesVCV, PCV, SIMV, PSV, CPAP, PRVC, APRV
Tidal volume range (VT)20 – 2000 mL with near-patient volume measurement
Respiratory rate1 – 80 breaths/min
PEEP / FiO2PEEP 0 – 40 cmH2O · FiO2 21 – 100 %
DisplayLarge screen showing several waveforms simultaneously
ConnectivityConnects to the ICU central station
AS-V1Transport Ventilator · ICU & Transport Ventilator
TypeTransport ventilator
Tidal volume range (VT)50 – 1500 mL
Respiratory rate1 – 50 breaths/min
PEEP / FiO2PEEP 0 – 20 cmH2O · FiO2 21 – 100 %
Battery4 – 6 hours of continuous use (depending on operating conditions)
Weight / durabilityCompact structure with carry handle, resistant to vibration during transport
AS-NVNon-invasive · ICU & Transport Ventilator
TypeNon-invasive ventilator (NIV)
ModesCPAP, S, T, ST
Pressure rangeIPAP 4 – 30 cmH2O · EPAP 4 – 20 cmH2O
Backup respiratory rate4 – 40 breaths/min
FiO221 – 100 %
Patient interfaceNasal mask / oronasal mask (ordered separately by size)
Prepared by Abyssalmed Product DivisionLast updated 16 November 2026
Technical reviewer The manufacturer's Clinical Engineering department — the reviewer's name and sign-off date are stated in the Technical Data Sheet supplied with the quotation
Source references Datasheet and Instructions for Use (IFU) for every model listed above — the full PDF files are available by email
Disclaimer Information on patient suitability (for example use with neonates) and consumable replacement intervals must follow the instructions for use of that model and the judgement of the treating physician; it is not the marketing copy on this page
PART 04

Frequently Asked Questions

Answers are based on the instructions for use and datasheets of the models listed on this page. For anything concerning neonatal patients or consumable replacement intervals, please confirm against the manual supplied with the device and the judgement of the treating physician.

Can it be used with pediatric patients?
The AS-V3 supports pediatric patients with appropriate volume and respiratory rate settings. A separate pediatric breathing circuit should be selected.
Are there modes for spontaneously breathing patients?
The AS-NV offers CPAP and non-invasive ventilation modes, which suit patients who are still breathing spontaneously.
Is user training available?
Basic user training is available for medical and nursing teams, together with multilingual manuals and demonstration videos.
How often should consumables be replaced?
Breathing circuits and filters should be changed according to the hospital's infection control policy, typically every 3–7 days.
Contact us

Request a quote — Ventilators

Tell us the unit quantity, destination country and preferred payment terms. We will reply with a quotation and the document list within one business day.

Emailwanlinfirecontrol@163.com
Phone+86 132 6167 7119
WhatsApp+86 132 6167 7119