A AbyssalmedMEDICAL EQUIPMENT
Home/Products/Anesthesia Machines

Anesthesia Machines
for Operating Theatres of Every Tier

Gas delivery, ventilation and safety monitoring combined in a single unit, covering general, minor and specialized surgery.

Operating TheatreAnesthesiologyDay SurgeryDelivery Room
PART 01

Available Models

Choose the tier by the type of surgery the hospital provides — from basic models to those with a full display and data recording.

AS-A400
Basic

An anesthesia machine with an integrated ventilator, for general operating theatres and community hospitals.

  • 1–2 vaporizer positions
  • VCV and SIMV modes
  • Leak-check system
  • Robust, mobile structure
AS-A500
Standard

The model used in general hospitals, with a screen displaying ventilation values and a complete alarm system.

  • Color screen with waveforms
  • EtCO2 and agent monitoring
  • Surgical data recording
  • HIS connectivity supported
AS-A600
Advanced

The model for university hospitals and specialist medical centers, with a full set of ventilation modes and multi-layer monitoring.

  • Complete set of ventilation modes
  • Automatic gas delivery monitoring
  • Large display
  • Data backup system
AS-A900
Workstation

A fully equipped anesthesia machine with surgical data management and hospital system connectivity.

  • Multiple integrated displays
  • Record and export data
  • Supports complex surgery
  • Designed to international standards
PART 02

Clinical Applications

Choose according to the tier of the facility and the patient profile it handles; our sales team can advise on the basis of actual use.

General operating theatre

The AS-A400 and AS-A500 are sufficient for general and minor surgery in community and general hospitals.

Specialized surgery

The AS-A600 is used in university hospitals performing complex surgery that requires detailed parameter monitoring.

Delivery room

Used together with regional anesthesia for caesarean sections where required.

Medical center

The AS-A900 combines data management and hospital system connectivity in a single unit.

PART 03

Technical Data by Model

Each model has its own table. The values shown are those declared by the manufacturer in the model datasheet, not independent test results — please confirm the values your clinical use depends on in the quotation before ordering.

AS-A400Basic · Anesthesia Machine
Vaporizer1 position (sevoflurane or isoflurane)
Ventilation modesVCV, SIMV, Manual
Tidal volume range (VT)50 – 1500 mL
Respiratory rate4 – 40 breaths/min
MonitoringFiO2, volume, circuit pressure
Display10.4-inch color screen
AS-A500Standard · Anesthesia Machine
Vaporizer2 positions
Ventilation modesVCV, PCV, SIMV, PSV, Manual
Tidal volume range (VT)50 – 1500 mL
Respiratory rate4 – 40 breaths/min
MonitoringFiO2, EtCO2, volume, pressure, agent identification
ConnectivityConnects to the hospital HIS
AS-A600Advanced · Anesthesia Machine
Vaporizer2 positions with an interlock against agent interchange
Ventilation modesVCV, PCV, SIMV, PSV, PRVC, Manual
Tidal volume range (VT)20 – 1500 mL
Respiratory rate1 – 60 breaths/min
MonitoringFiO2, EtCO2, agent ID, volume, pressure
Display15-inch color screen with several waveforms
AS-A900Workstation · Anesthesia Machine
Vaporizer2 – 3 positions (depending on configuration)
Ventilation modesVCV, PCV, SIMV, PSV, PRVC, APRV, Manual
Tidal volume range (VT)20 – 1500 mL
Respiratory rate1 – 80 breaths/min
Data systemRecords and exports the anesthesia record, connects to hospital systems
DisplayDual screen (device screen + data screen)
Prepared by Abyssalmed Product DivisionLast updated 16 November 2026
Technical reviewer The manufacturer's Clinical Engineering department — the reviewer's name and sign-off date are stated in the Technical Data Sheet supplied with the quotation
Source references Datasheet and Instructions for Use (IFU) for every model listed above — the full PDF files are available by email
Disclaimer Information on patient suitability (for example use with neonates) and consumable replacement intervals must follow the instructions for use of that model and the judgement of the treating physician; it is not the marketing copy on this page
PART 04

Frequently Asked Questions

Answers are based on the instructions for use and datasheets of the models listed on this page. For anything concerning neonatal patients or consumable replacement intervals, please confirm against the manual supplied with the device and the judgement of the treating physician.

What monitoring does it need to be used with?
The AS-A500 and above have built-in EtCO2 and agent monitoring. The basic models can be connected to an external monitor.
Can the vaporizer be changed?
Yes. Vaporizers can be changed or added to match the agents the hospital uses. The agent type and concentration must be specified at the time of ordering.
Is there an N2O cut-off system?
Every model has automatic N2O cut-off when FiO2 falls below the set threshold, to prevent hypoxia.
What preparations does installation require?
A medical gas supply, a gas scavenging system and a well-ventilated area are required.
Contact us

Request a quote — Anesthesia Machines

Tell us the unit quantity, destination country and preferred payment terms. We will reply with a quotation and the document list within one business day.

Emailwanlinfirecontrol@163.com
Phone+86 132 6167 7119
WhatsApp+86 132 6167 7119
Business hoursMon–Sat 09:00–18:00 (GMT+8)