Monitor several vital signs at once on a single screen, with real-time ECG and blood oxygen waveforms and alarms that can be graded by severity.
Choose by the number of parameters to be monitored and the screen size. The neonatal model uses sensors and measurement ranges designed specifically for infants.
A compact model for examination rooms and mobile trolleys, measuring ECG, SpO2, NIBP and respiratory rate.
The standard model for intensive care units, monitoring six core parameters simultaneously with central station connectivity.
A large-screen model for operating theatres and advanced critical care, displaying more waveforms simultaneously.
Designed specifically for neonates, with SpO2 and blood pressure measurement ranges suited to low-birth-weight infants.
Choose according to the tier of the facility and the patient profile it handles; our sales team can advise on the basis of actual use.
Continuous 24-hour monitoring connected to a central station, so nurses see the values from every bed in one place.
Monitoring during anesthesia and recovery, with trend recording to support the medical record.
Use the compact model, which moves easily between emergency bays and the X-ray room.
Use the AS-MN, whose measurement ranges suit infants, with small sensors that do not press on the skin.
Each model has its own table. The values shown are those declared by the manufacturer in the model datasheet, not independent test results — please confirm the values your clinical use depends on in the quotation before ordering.
| Screen size | 7-inch high-resolution touchscreen |
|---|---|
| Parameters | ECG, Resp, SpO2, NIBP, 2×Temp (depending on configuration) |
| SpO2 range | 70 – 100 %, accuracy ±2 % (70–100 % range) |
| NIBP | Adult / pediatric / neonatal modes |
| Recording | 72-hour trends, event memory |
| Battery | Approximately 4 hours of continuous use |
| Screen size | 12.1-inch touchscreen |
|---|---|
| Parameters | ECG 7-lead, Resp, SpO2, NIBP, 2×Temp, IBP (optional) |
| SpO2 range | 70 – 100 %, accuracy ±2 % (70–100 % range) |
| NIBP | Adult / pediatric / neonatal modes with interval measurement |
| Connectivity | LAN / Wi-Fi for central station connection (sub-model dependent) |
| Battery | Approximately 5 hours of continuous use |
| Screen size | 15.6-inch touchscreen |
|---|---|
| Parameters | ECG, Resp, SpO2, NIBP, 2×Temp, up to 4 IBP channels, EtCO2 (optional) |
| Display | Multiple simultaneous layouts, dual-screen support |
| Connectivity | LAN / Wi-Fi / HL7 to the HIS |
| Recording | 120-hour trends, event waveform capture |
| Battery | Approximately 5 hours of continuous use |
| Screen size | 10.4-inch touchscreen |
|---|---|
| Patient group | Neonates and infants — measurement ranges adjusted for small patients |
| SpO2 range | 70 – 100 %, accuracy ±2 %, with neonatal-size sensor |
| NIBP | Neonatal mode (low pressure range) with small cuff |
| Parameters | ECG, Resp, SpO2, NIBP, 2×Temp |
| Alarms | Volume and priority configurable for the neonatal unit |
Answers are based on the instructions for use and datasheets of the models listed on this page. For anything concerning neonatal patients or consumable replacement intervals, please confirm against the manual supplied with the device and the judgement of the treating physician.
Tell us the unit quantity, destination country and preferred payment terms. We will reply with a quotation and the document list within one business day.