The core equipment of the neonatal intensive care unit (NICU), with fine control of temperature, humidity and oxygen levels, plus alarm systems that help nurses respond in time.
Three main groups to choose from by application: stationary incubators, radiant warmers for the delivery room, and transport incubators for inter-hospital transfer.
A stationary neonatal incubator with skin-mode and air-mode temperature control and a display showing several values simultaneously.
A radiant warmer for delivery rooms and neonatal procedure rooms, with multi-level heat output adjustment.
An incubator for transporting infants between delivery rooms, operating theatres and hospitals, powered by an internal battery.
A phototherapy unit for neonatal jaundice that delivers uniform light intensity across the skin surface.
Choose according to the tier of the facility and the patient profile it handles; our sales team can advise on the basis of actual use.
The AS-100 incubator is the mainstay for low-birth-weight infants requiring round-the-clock environmental control, with the AS-400 added when jaundice is present.
The AS-200 delivers immediate warmth after birth, during assessment and neonatal resuscitation.
The AS-300 maintains body temperature during ambulance transfer — the period in which an infant loses heat most readily.
Start with one or two incubators and a phototherapy unit to cover normal deliveries, and refer complex cases onward.
Each model has its own table. The values shown are those declared by the manufacturer in the model datasheet, not independent test results — please confirm the values your clinical use depends on in the quotation before ordering.
| Air temperature range | 25 – 37 °C, adjustable in 0.1 °C steps |
|---|---|
| Temperature stability | ±0.5 °C under controlled conditions |
| Relative humidity | 30 – 75 % RH (evaporative water system) |
| Infant weight per manual | Up to 4 kg for this model |
| Construction | Double-walled, hood opens on two sides |
| Alarm system | High/low temperature, power failure, fan fault, door open |
| Air temperature range | 25 – 38 °C, adjustable in 0.1 °C steps |
|---|---|
| Temperature stability | ±0.3 °C under controlled conditions |
| Relative humidity | 30 – 85 % RH, servo-controlled |
| Infant weight per manual | Up to 5 kg for this model |
| Control | Skin-temperature servo-control with two skin sensors |
| Alarm system | Adds humidity and skin-temperature alarms |
| Air temperature range | 25 – 38 °C |
|---|---|
| Relative humidity | 30 – 90 % RH, automatic |
| Infant weight per manual | Up to 6 kg for this model |
| Additional functions | Integrated weighing, tray-based X-ray imaging (sub-model dependent) |
| Display | Color touchscreen with historical temperature trends |
| Reference standards | IEC 60601-1, IEC 60601-1-2, IEC 60601-2-19 |
| Air temperature range | 25 – 39 °C |
|---|---|
| Relative humidity | 30 – 90 % RH, automatic |
| Infant weight per manual | Up to 8 kg for this model |
| Combined operation | Designed to work with the phototherapy bassinet in the same set |
| Data logging | Seven-day trend recording with data export |
| Reference standards | IEC 60601-1, IEC 60601-1-2, IEC 60601-2-19, IEC 60601-2-50 |